HV De-Energisation

HV De-Energisation (HV-Freischaltung): The mandatory safety procedure for shutting down and locking out a vehicle's high-voltage system before any maintenance work. Only a qualified FHV specialist (Level 2S+) may perform it. Every de-energisation must be documented in a test record.

The 5-Step De-Energisation Procedure

DGUV 209-093 and manufacturer-specific work instructions define the exact steps. The following reflects the general sequence – always follow the vehicle-specific manual:

  1. Identify the vehicle and assess hazards – confirm the vehicle type, battery voltage level (typically 400 V or 800 V DC) and check the risk assessment is current
  2. Don PPE – put on Class 0 insulating gloves (EN 60903), safety glasses and insulated work boots before approaching the HV system
  3. Activate the service disconnect / manual service disconnect (MSD) – follow the manufacturer's procedure exactly; this disconnects the battery from the HV circuit
  4. Wait for capacitor discharge – high-voltage capacitors in the inverter can retain dangerous charge; wait the time specified by the manufacturer (typically 5–10 minutes)
  5. Verify voltage-free state with a CAT III multimeter – measure at the prescribed test points; voltage must be below 60 V DC; record the reading in the test record

Who May Perform HV De-Energisation?

De-energisation is a core competency of the FHV (Fachkundige Person Hochvolt) qualification. The minimum requirements are:

An Fachkundig unterwiesene Person (FuP) (Level 1S) may not independently de-energise an HV vehicle and may not verify voltage-free state.

Required Equipment

Does de-energisation need to be documented every time?
Yes. Every de-energisation must be documented in a test record including the measured residual voltage, the instrument used, the FHV's name and signature, and the vehicle identification. This documentation is not merely best practice – it is an employer liability requirement under BetrSichV.
Can the vehicle be re-energised after de-energisation without a new procedure?
No. If an HV vehicle is reconnected (re-energised) after de-energisation, the full de-energisation procedure must be repeated before further work begins. The voltage-free state cannot be assumed to persist once the work area has been left or the vehicle has been accessed by another person.